TECHNICAL DATA
Lifetime: | 50.000 switching cycles | Working range: | 0-150 °C / 50-400 °C |
Switching power: | 20(4)A-4(1)A/250 V~; | Sensor: | Tubular type: Cu: Ø5; Ø6; Ø8 |
16(4)A-4(1)A/400 V~; | INOX: Ø3; Ø4; Ø6 | ||
Way of operation: | 2 C | Capillary tube: | Ø 1,4 (Cu) / Ø 1 (INOX) |
Max. temp. for the main unit: | 85 °C / 150 °C | Capillary tube length: | 250-2400 |
Protection class: | Class I. / IP 00 | Max. sensor temperature: | Upper switching value +15% |
Operation environment: | Normal | Surface protection: | Galvanized |
Heat and fire resistance: | D | Lenght of the shaft: | 16-50 |
Leakage current resistance: | ≥ 175 | Electrical connections: | Blades, A 6,3×0,8 |
TYPE EXAMPLES
Type Code | Type mark | Switch-off temp. °C |
∆T | Sensor ØDx L1/mm/ Material |
Capillary tube Ød x L2 /mm/ |
Protection tube L3 ± 20 /mm/ |
Lenght of the shaft Lt /mm/ |
Wiring diagram M/ A |
5270-0-101-1 | TC-1R31KM | 50 – 280 ± 6 | 10 ± 4 | 4 x 168 INOX | 1 x 420 | 20 | 25 | M |
5270-0-101-4 | TC-1R31KM | 50 – 300 ± 6 | 10 ± 4 | 4 x 168 INOX | 1 x 1500 | 20 | 25 | M |
5270-0-101-9 | TC-1R31KM | 50 – 280 ± 6 | 10 ± 4 | 4 x 168 INOX | 1 x 920 | 20 | 25 | M |
5270-0-104-4 | TC-1R31KM | 50 – 190 ± 6 | 10 ± 4 | 6 x 95 INOX | 1 x 600 | 20 | 25 | M |
5270-0-104-8 | TC-1R31KM | 50 – 190 ± 6 | 10 ± 4 | 6 x 95 INOX | 1 x 920 | 20 | 25 | M |
5270-0-105-0 | TC-1R31KM | 50 – 220 ± 6 | 10 ± 4 | 6 x 95 INOX | 1 x 920 | 20 | 22,5 | M |
5270-0-113-4 | TC-1R30KM | 50 – 110 ± 4 | 4 ± 2 | 6 x 165 INOX | 1v x 920 | 730 | 25 | M |
5270-0-114-2 | TC-1R30KMS | P1-1 20 – 80 ± 3 | 4 ± 2 | 8 x 88 Cu | 1,4 x 920 | 120 | 24 | M |
P2-2 25 – 85 ± 3 | ||||||||
P3-3 30 – 90 ± 3 | ||||||||
5270-0-118-4 | TC-1R31KM | 50 – 230 ± 6 | 12 ± 4 | 3 x 281 INOX | 1 x 920 | 40 | 24,5 | M |
5270-0-131-1 | TC-1R31KM | 50 – 300 ± 6 | 10 ± 4 | 4 x 168 INOX | 1 x 920 | 810 | 25 | M |