TECHNICAL DATA
Lifetime: | 50.000 switching cycles | Working range: | 0-150 °C / 50-400 °C |
Switching power: | 20(4)A-4(1)A/250 V~; | Sensor: | Tubular type: Cu: Ø5; Ø6; Ø8 |
16(4)A-4(1)A/400 V~; | INOX: Ø3; Ø4; Ø6 | ||
Way of operation: | 2 C | Capillary tube: | Ø 1,4 (Cu) / Ø 1 (INOX) |
Max. temp. for the main unit: | 85 °C / 150 °C | Capillary tube length: | 250-2400 |
Protection class: | Class I. / IP 00 | Max. sensor temperature: | Upper switching value +15% |
Operation environment: | Normal | Surface protection: | Galvanized |
Heat and fire resistance: | D | Lenght of the shaft: | 16-50 |
Leakage current resistance: | ≥ 175 | Electrical connections: | Blades, A 6,3×0,8 |
TYPE EXAMPLES
Type Code | Type mark | Switch-off temp. °C |
∆T | Sensor ØD x L1/mm/; Material |
Capillary tube ØdxL2 /mm/ |
Protection tube L3 ±20 /mm/ |
Lenght of the shaft Lt /mm/ |
Wiring diagram M/A |
Ear position F0/F90 |
5285-0-204-3 | TC-1R20PAS | P1-1 46 – 85 ± 3 | 4 ± 2 | 6,5 x 93 Cu | 1,4 x 1080 | 490 | 16 | A | F90 |
P2-2 39 – 78 ± 3 | |||||||||
5285-0-204-6 | TC-1R20PA | 0 – 40 ± 3 | 1,5 ± 0,5 | 6 x 188 Cu | 1,4 x 920 | 850 | 16 | A | F90 |
5285-0-204-7 | TC-1R20PA | 7 – 55 ± 3 | 4 ± 2 | 6 x 107 Cu | 1,4 x 1080 | 830 | 20 | A | F0 |