TECHNICAL DATA
Lifetime: | 1000 switching cycles | Electrical connections: | Blades, A 6,3×0,8 |
Switching power: | 20(4)A-4(1)A/250 V~; | Sensor: | Tubular type: Cu: Ø5; Ø6; Ø6,5; Ø8 |
16(4)A-4(1)A/400 V ~ | INOX: Ø3; Ø4; Ø6 | ||
Leakage current resistance: | ≥ 175 | Working range: | 0-150 °C /50-355 °C |
Way of operation | 2 AG /2AGM | Capillary tube: | Ø 1,4 (Cu) / Ø 1 (INOX) |
Max. temp. for the main unit: | 85 °C / 150 °C | Capillary tube length: | 250 – 2400 |
Protection class: | Class I. / IP 00 | Max. sensor temperature: | Upper switching value +15% |
Work environment: | Normál | Surface protection: | Galvanized |
Heat and fire resistance: | D |
TYPE EXAMPLES
Type Code | Type mark | Switch-off temp. °C |
Sensor ØDxL1/mm/; Material |
Capillary tube ØdxL2 /mm/ |
Protection tube L3 ± 20 /mm/ |
Wiring diagram M / A |
Special accessory |
|
5286-0-103-1 | TC-1SB20PM | 110 | 0 | 6 x 103 Cu | 1,4 x 250 | 210 | M | FL |
-10 | ||||||||
5286-0-103-5 | TC-1SB20PM | 110 | 0 | 6 x 103 Cu | 1,4 x 250 | 210 | M | – |
-10 | ||||||||
5286-0-104-1 | TC-1SB20PM | 100 | 0 | 6 x 103 Cu | 1,4 x 550 | 480 | M | – |
-10 | ||||||||
5286-0-108-1 | TC-1SB21PM | 242 | 0 | 3 x 214 INOX | 1 x 420 | 40 | M | – |