TECHNICAL DATA
Lifetime: | 50.000 switching cycles | Working range: | -35-77 °C / 0-150 °C / 25-400 °C |
Switching power: | 20(4)A-4(1)A/250 V~ | Sensor: | Tubular: Cu: Ø 5; Ø 6; Ø 8 |
16(4)A-4(1)A/400 ~V | INOX: Ø 3; Ø 4; Ø 6 | ||
Way of operation: | 2BL | Capillary tube: | Ø 1,4 (Cu) / Ø 1 (INOX) |
Max.temp. for the main unit: | 85 °C / 150 °C | Capillary tube length: | 250-2400 |
Protection class: | Class I. / IP 00 | Max. sensor temperature: | Upper switching value +15% |
Operation environment: | Normal | Surface protection: | Galvanized |
Heat and fire resistance: | D | Lenght of the shaft: | 16 – 50 |
Leakage current resistance: | ≥175 | Electrical connections: | Blades, A 6,3×0,8 |
TYPE EXAMPLES
Type Code | Type mark | Switch-off temp. °C |
∆T | Sensor ØD x L1/mm/ Material |
Capillary tube Ød x L2 /mm/ |
Protection tube L3 ± 20 /mm/ |
Lenght of the shaft Lt /mm/ |
Wiring diagram M / A |
Contacts B / C / S |
|
4111-0-001-0 | HU-20-M | 5 – 80 | 0 | 4 ± 2 | 6,5 x 113 Cu | 1,4 x 565 | 485 | 16 | M | B |
-6 | ||||||||||
4111-0-001-1 | HU-20-M | 5 – 80 | 0 | 4 ± 2 | 6,5 x 113 Cu | 1,4 x 565 | 485 | 16 | M | C |
-6 | ||||||||||
4125-0-002-0 | HU-30-M | 50 – 320 | +10 | 8 ± 2 | 3 x 164 INOX | 1 x 935 | 45 | 24 | M | B |
-2 | ||||||||||
4101-0-004-0 | HU-10-A | -35 – 30 | ±3 | 2 ± 1,5 | 6,5 x 113 Cu | 1,4 x 565 | 485 | 16 | A | S |
4125-0-019-0 | HU-30-M | 50 – 190 | ±8 | 8 ± 2 | 4 x 128 INOX | 1 x 665 | 15 | 24 | M | B |
4111-0-024-0 | HU-20-M | 7 – 71 | ±3 | 4 ± 2 | 6 x 100 Cu | 1,4 x 665 | 485 | 16 | M | B |
4111-0-037-0 | HU-20-M | 20 – 120 | ±4 | 4 ± 2 | 5 x 132 Cu | 1,4 x 935 | 255 | 16 | M | B |
4111-0-038-0 | HU-20-A | 30 – 90 | ±4 | 6 ± 2 | 6,5 x 113 Cu | 1,4 x 935 | 315 | 23 | A | B |
4111-0-039-0 | HU-30-M | 60 – 160 | ±6 | 7 ± 3 | 6 x 100 Cu | 1,4 x 935 | 255 | 16 | M | B |
4111-0-043-0 | HU-20-M | 5 – 54 | 10 ± 4 | 6,5 x 116 Cu | 1,4 x 565 | 485 | 16 | M | B | |
4111-0-049-0 | HU-30-A | 50 – 250 | ±6 | 10 ± 4 | 3 x 219 INOX | 1 x 935 | 45 | 24 | A | B |