TECHNICAL DATA
Lifetime: | 1000 switching cycles | Working range: | 0-150 °C / 50-355 °C |
Switching power: | 20(4)A-4(1)A/250 V~ | Sensor: | Tubular: Cu: Ø 5; Ø 6; Ø 8 |
16(4)A-4(1)A/400 ~V | INOX: Ø 3; Ø 4; Ø 6 | ||
Way of operation: | 2BG | Capillary tube: | Ø 1,4 (Cu) / Ø 1 (INOX) |
Max.temp. for the main unit: | 85 °C / 150 °C | Capillary tube length: | 250-2400 |
Protection class: | Class I. / IP 00 | Max. sensor temperature: | Upper switching value +15% |
Operation environment: | Normal | Surface protection: | Galvanized |
Heat and fire resistance: | D | Electrical connections: | Blades, A 6,3×0,8 |
Leakage current resistance: | ≥175 |
TYPE EXAMPLES
Type Code | Type mark | Switch-off temp. °C |
Sensor ØD x L1/mm/; Material |
Capillary tube Ød x L2 /mm/ |
Protection tube L3 ± 20 /mm/ |
Wiring diagram M / A |
|
5279-0-003-2 | TC-1B11KM | 220 | 0 | 4 x 168 Inox | 1 x 580 | 460 | M |
+/-6 | |||||||
5279-0-003-3 | TC-1B11KM | 246 | 0 | 4 x 100 Inox | 1 x 420 | 20 | M |
-15 | |||||||
5279-0-003-6 | TC-1B11KM | 350 | 0 | 4 x 91 Inox | 1 x 1600 | 1260 | M |
-15 | |||||||
5279-0-004-8 | TC-1B11KM | 320 | 0 | 6 x 98 Inox | 1 x 920 | 50 | M |
+/-9 | |||||||
5279-0-004-9 | TC-1B11KM | 220 | 0 | 4 x 168 Inox | 1 x 1920 | 1760 | M |
+/-6 | |||||||
5279-0-005-1 | TC-1B11KM | 150 | 0 | 3 x 215 Inox | 1 x 920 | 860 | M |